2,899 research outputs found

    Numerical modelling of multiple standing column wells for heating and cooling buildings

    Get PDF
    A model for simulating clusters of standing column wells (SCWs) for use in geothermal heating and cooling systems is described in this paper. The model is three-dimensional, dynamic and solves the governing equations using a finite volume discretisation scheme with a fully implicit algorithm. The slower-acting field equations are solved using a wider time interval than that used for the faster-acting well equations and the two sets of equations are coupled through the field equation source terms. A groundwater bleed feature is incorporated. The model is applied to two evaluative test cases the first of which involves heating only and the second, heating and cooling. Results of the applications suggest that SCWs can deliver substantially higher rates of heat transfer than conventional closed loop borehole heat exchanger arrays especially when groundwater bleed is operational. An important practical consequence of this is that far less geotechnical drilling is needed when using SCWs than is the case with closed loop arrays

    A General Framework for Updating Belief Distributions

    Full text link
    We propose a framework for general Bayesian inference. We argue that a valid update of a prior belief distribution to a posterior can be made for parameters which are connected to observations through a loss function rather than the traditional likelihood function, which is recovered under the special case of using self information loss. Modern application areas make it is increasingly challenging for Bayesians to attempt to model the true data generating mechanism. Moreover, when the object of interest is low dimensional, such as a mean or median, it is cumbersome to have to achieve this via a complete model for the whole data distribution. More importantly, there are settings where the parameter of interest does not directly index a family of density functions and thus the Bayesian approach to learning about such parameters is currently regarded as problematic. Our proposed framework uses loss-functions to connect information in the data to functionals of interest. The updating of beliefs then follows from a decision theoretic approach involving cumulative loss functions. Importantly, the procedure coincides with Bayesian updating when a true likelihood is known, yet provides coherent subjective inference in much more general settings. Connections to other inference frameworks are highlighted.Comment: This is the pre-peer reviewed version of the article "A General Framework for Updating Belief Distributions", which has been accepted for publication in the Journal of Statistical Society - Series B. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Self-Archivin

    Interact: A Mixed Reality Virtual Survivor for Holocaust Testimonies

    Get PDF
    In this paper we present Interact---a mixed reality virtual survivor for Holocaust education. It was created to preserve the powerful and engaging experience of listening to, and interacting with, Holocaust survivors, allowing future generations of audience access to their unique stories. Interact demonstrates how advanced filming techniques, 3D graphics and natural language processing can be integrated and applied to specially-recorded testimonies to enable users to ask questions and receive answers from that virtualised individuals. This provides a new and rich interactive narratives of remembrance to engage with primary testimony. We discuss the design and development of Interact, and argue that this new form of mixed reality is promising media to overcome the uncanny valley

    High-Q optical resonators in silicon-on-insulator-based slot waveguides

    Get PDF
    This letter describes the design, fabrication and characterization of high-Q oval resonators based on slot waveguide geometries in thin silicon-on-insulator material. Optical quality factors of up to 27 000 were measured in such filters, and we estimate losses of –10 dB/cm in the slotted waveguides on the basis of our resonator measurements. Such waveguides enable the concentration of light to very high optical fields within nanoscale dimensions, and show promise for the confinement of light in low-index material with potential applications for optical modulation, nonlinear optics and optical sensing

    High-Q ring resonators in thin silicon-on-insulator

    Get PDF
    We have fabricated high-Q microrings from thin silicon-on-insulater SOI layers and measured Q values of 45 000 in these rings, which were then improved to 57 000 by adding a PMMA cladding. The optimal waveguide designs were calculated, and the waveguide losses were analyzed. These high-Q resonators are expected to lead to interesting devices for telecommunication filters and sources as well as optical refractive index sensing

    Recommendations for high intensity upper body exercise testing

    Get PDF
    Introduction: For given submaximal and maximal peak power outputs aerobic responses to upper body exercise are different to those for lower body exercise (Sawka, 1986: Exercise & Sport Sciences Reviews, 14, 175-211). However, much less is known regarding responses to exercise intensities at and around peak oxygen up take (VO2peak). Purpose: The purpose of this study was to determine the metabolic responses during arm crank ergometry (ACE) below, at and above peak oxygen uptake and to help establish exercise testing guidelines for high intensity upper body exercise. Methods: Following institutional ethical approval fourteen male students (Age 21.1, s = 6.1 years and 2.44 s=0.44 VO2peak) volunteered to take part in this study. Each participant exercised on a table mounted cycle ergometer (Monark 894E, Monark Exercise AB, Sweden). After habituation peak minute power (PMP) was calculated from an incremental test. Subsequently each participant completed four continuous work tests (CWT) to volitional exhaustion at 80%, 90%, 100% and 110% of PMP. All tests were completed at 70 rev∙min-1 with a minimum of 48-h between tests and the order was counterbalanced. Each CWT was preceded by a 5 min warm-up, loaded with a mass corresponding to the participants 80% PMP for 20 s at minutes 2, 3 and 4. Oxygen uptake (VO2), respiratory exchange ratio (RER), heart rate (HR) and ratings of perceived exertion for the arms (local (RPEL) and cardiorespiratory strain (RPECR) were recorded at 1 min, 2 min and at volitional exhaustion. The EMG responses at three sites (flexor carpi ulnaris, biceps brachii and triceps brachii lateral) were recorded using double-differential (16-3000 Hz bandwidth, x300 gain), bipolar, active electrodes (MP-2A, Linton, Norfolk, UK). Electromyographic data were sampled at 1000 Hz and filtered using a 20 to 500 Hz band-pass filter (MP150 Data Acquisition and AcqKnowledge 4.0, Biopac, Goleta, CA). The EMG signals for each muscle were root mean squared (RMS) with a 500-ms sample window. The signal was then normalised, prior to each CWT, as a percentage of the mean of 3 sets of 10 duty cycles completed during the warm-up (see above) when the participants 80% PMP for 20 s was applied. Time to exhaustion (Tlim) was recorded as the performance outcome measure. Data for Tlim were analysed using one-way analysis of variance. Differences in EMG, VO2, RER, HR, RPEL and RPECR were analysed using separate two-way analysis of variance with repeated measures (trial x time). All analyses were performed using the Statistical Package for Social Sciences ( 17.0; SPSS Inc., Chicago, IL). Individual differences in means were located using Bonferroni post-hoc correction. Significance was accepted at P < 0.05. Results: As resistive load increased Tlim decreased (611 s=194, 397 s=99, 268 s=90, 206 s=67s, respectively; P < 0.001, ES = 0.625). Post-hoc analysis revealed that Tlim using 80%PMP was longer than for 90%, 100% and 110% PMP trials (P < 0.001) and 90% was longer than both 100% and 110% PMP trials (P = 0.079, P = 0.001). At exhaustion VO2 was similar across trials (P = 0.413, ES = 0.053), although 80% PMP VO2 tended to be less (2.10 s=0.32 l·min-1) than for 90% (2.29 s=0.37), 100% (2.33 s=0.49) and 110% (2.26 s=0.34). Also, 80% PMP VO2 was less than VO2peak (P = 0.013). There were differences in RER at Tlim (P < 0.001, ES = 0.593) with values increasing with % PMP (1.15 s=0.07, 1.26 s=0.07, 1.36 s=0.10, 1.40 s=0.09, respectively). There were no differences across trials for HR at Tlim (~173 (12); P = 0.834, ES = 0.016) and HR was proportional to %PMP at 1 min, and 2 min. For flexor carpi ulnaris there was an increase in activation as exercise intensity increased (P < 0.001, ES = 0.245). There were a similar responses for biceps brachii and triceps brachii demonstrating an increase in activation with exercise intensity (P <0.001, ES = 0.137, P < 0.001, ES = 0.163, respectively). No differences for RPEL and RPECR were observed at Tlim. Discussion: There was a clear response of Tlim with intensity as expected for lower body exercise (Hill et al., 2002: Medicine and Science in Sports and Exercise, 34(4), 709-714). Despite differences in Tlim across exercise intensities VO2, HR and RPE were similar at exhaustion indicating a functional cardiorespiratory maximum had been reached. As indicated by the RER an increased activation of the anaerobic metabolism with greater exercise intensities (100% and 110%) is likely and therefore this may represent a greater anaerobic component at these two intensities. The increase in EMG activity with intensity could indicate an increase activity with an increase in exercise intensity. Conclusion: It is recommended that due to the combination of muscle activation, oxygen uptake and Tlim that an exercise intensity of 90% or 100% of PMP could be used for high intensity upper body exercise testing

    Integrated plasmon and dielectric waveguides

    Get PDF
    We have designed, fabricated and characterized surface plasmon waveguides for near infrared light in the telecommunications spectrum. These waveguides exhibit losses of -1.2dB/μm and can guide light around 0.5 μm bends. Light can also be efficiently coupled between more conventional silicon waveguides and these plasmon waveguides with compact couplers, and we demonstrate that surface plasmon optical devices can be constructed by using planar circuit fabrication techniques. The large optical field enhancements of metallic surface plasmon devices are expected to lead to a new class of plasmonic optical devices, which will take advantage of the large field enhancements at the surfaces of the plasmon waveguides for nonlinear or sensing functionality, while utilizing the low losses available in silicon waveguides to move light longer distances on chip

    Poems

    Get PDF
    Poems include: You\u27re in the Winter, by Chris Kleinschmidt and Plan for Tomorrow, by Brian Walke

    Response of idealized Hadley circulations to seasonally varying heating

    Get PDF
    [1] The response of Hadley circulations to displacements of the latitude of maximum heating is investigated in idealized axisymmetric and eddy-permitting models. Consistent with an earlier study and with theory for the nearly inviscid limit (Lindzen and Hou, 1988), the strength of the Hadley circulation is sensitive to displacements of heating: the winter cell strengthens and summer cell weakens when the maximum heating is displaced off the equator. However, in conflict with the nearly inviscid limit but consistent with observations of Earth's atmosphere, the strength of an annually averaged Hadley circulation is comparable to the Hadley circulation driven by an annually averaged heating. The disagreement between these results and the nearly inviscid limit is ascribed to vertical diffusion of momentum and dry static energy in the axisymmetric model and to baroclinic eddy fluxes in the eddy-permitting model. Nonlinear amplification of the annually averaged Hadley circulation is only seen near the upper boundary in simulations with a rigid lid near the tropopause, suggesting that the amplification is an artifact of the upper boundary condition
    • …
    corecore